On the Stream Gage, water quality constituents are transferred through the object. In this approach, there are no dispatch methods. Water quality constituent values are transferred via links. You should link the constituent slot to both the upstream and downstream slots.
Slots
Temperature Slots
Heat
Type: Series Slot
Units: Heat
Description: Heat associated with the gage
I/O: Input, set by a rule, or propagated via a link
Salinity Slots
Salt Concentration
Type: Series Slot
Units: Concentration
Description: Salt concentration associated with the flow at the gage
I/O: Input, set by a rule, or propagated via a link
Dissolved Oxygen Slots
Ammonia Mass
Type: Series Slot
Units: Mass
Description: Ammonia mass associated with the flow at the gage
I/O: Input, set by a rule, or propagated via a link
Detritus Mass
Type: Series Slot
Units: Mass
Description: Detritus mass associated with the flow at the gage
I/O: Input, set by a rule, or propagated via a link
Dissolved Organics Mass
Type: Series Slot
Units: Mass
Description: Dissolved organics mass associated with the flow at the gage
I/O: Input, set by a rule, or propagated via a link
Dissolved Oxygen Mass
Type: Series Slot
Units: Mass
Description: Dissolved oxygen mass associated with the flow at the gage
I/O: Input, set by a rule, or propagated via a link
User Methods
The following section describes the user-selectable methods for water quality modeling on the Stream Gage.
Stream Gage Water Quality
Methods in this category are used to select the constituent and approach.
* None
No water quality solution is performed. No slots are added.
* Propagate Salt
All of the salt slots are added.
* Propagate Temperature
All of the temperature slots are added.
* Propagate Temp and Salt
All of the temperature and salt slots are added.
* Propagate Temp and DO
All of the temperature and DO slots are added.
* Propagate Temp Salt and DO
All of the temperature, salt and DO slots are added.
Dispatch Methods
There are no dispatch methods for the Diversion Object. This object propagates information via links.You should link the constituent slot to slots on both the source and destination objects.
 
Revised: 06/03/2019