skip to main content
Objects and Methods : Water User : Standalone or No Structure Slots
Standalone or No Structure Slots
In addition to the general slots, the following slots exist for a standalone water user, or when the parent Agg Diversion Site has the No Structure method selected.
Note:  The No Structure method is the default linking structure.
 Depletion
Type: Series Slot
Units: Flow
Description: Amount of water consumed by the water user
Information:  
I/O: Output only
 Depletion Shortage
Type: Series Slot
Units: Flow
Description: Difference between the Depletion Requested and the Depletion
Information: This value is only calculated if Depletion Requested and Depletion are both valid.
I/O: Output only
 Diversion
Type: Series Slot
Units: Flow
Description: Amount of water actually taken (diverted) by the water user
Information:  
I/O: Optional; Can be input or calculated based on Diversion Requested and Incoming Available Water (see dispatch methods).
 Diversion Shortage
Type: Series Slot
Units: Flow
Description: Difference between the Diversion Requested and the Diversion
Information:  
I/O: Output only
 Incoming Available Water
Type: Series Slot
Units: Flow
Description: Water available to be diverted
Information: It is the user’s responsibility to link this slot to the appropriate slot on the object from which water is diverted if using No Structure.
I/O: Set via link
Revised: 08/02/2021