skip to main content
General Slots
 Available For Diversion
Type: SeriesSlot
Units: FLOW
Description: Amount of flow that can be diverted from an upstream Reach or Reservoir
Information:  
I/O: Optional; can be calculated or set by propagation across a link
 Diversion
Type: SeriesSlot
Units: FLOW
Description: Amount diverted from the Reach or Reservoir
Information:  
I/O: Output only
 Diversion Request
Type: SeriesSlot
Units: FLOW
Description: Diversion requested from an upstream Reach or Reservoir
Information: Can be set as an input, particularly if there is a Reach or Reservoir linked to the downstream end of the Diversion Object. If there is an AggDistributionCanal or WaterUser linked to the downstream end, the Diversion Request slot on the Diversion Object should be linked to either the Total Delivery Request slot on the AggDistributionCanal or the Diversion Request slot on the WaterUser.
I/O: Optional; can be input, calculated, or set by propagation across a link.
 Diversion Shortage
Type: Series Slot
Units: flow
Description: Amount that the Diversion Request is shorted
Information: Computed as the Diversion Request minus the Diversion
I/O: Output only
Revised: 07/05/2022