skip to main content
Slots
Temperature Slots
 Heat
Type: Series Slot
Units: Heat
Description: Heat associated with the gage
I/O: Input, set by a rule, or propagated via a link
Salinity Slots
 Salt Concentration
Type: Series Slot
Units: Concentration
Description: Salt concentration associated with the flow at the gage
I/O: Input, set by a rule, or propagated via a link
Dissolved Oxygen Slots
 Ammonia Mass
Type: Series Slot
Units: Mass
Description: Ammonia mass associated with the flow at the gage
I/O: Input, set by a rule, or propagated via a link
 Detritus Mass
Type: Series Slot
Units: Mass
Description: Detritus mass associated with the flow at the gage
I/O: Input, set by a rule, or propagated via a link
 Dissolved Organics Mass
Type: Series Slot
Units: Mass
Description: Dissolved organics mass associated with the flow at the gage
I/O: Input, set by a rule, or propagated via a link
 Dissolved Oxygen Mass
Type: Series Slot
Units: Mass
Description: Dissolved oxygen mass associated with the flow at the gage
I/O: Input, set by a rule, or propagated via a link
Revised: 07/09/2023