Conservation Pool Fill Factor
The methods in this category allow a conservation pool to be filled in part (generally in order to allow other storage accounts on the object to receive some of the conservation pool paper-water). Storage Accounts with the Fill Conservation Pool method or the Fill Conservation Pool with Diversions method selected make use of the Fill Factor. This category includes the following methods.
None
No fill factor is given. 1.0 is used.
Fill Factor is Scalar
This method allows the user to specify a fixed fill factor in the scalar slot.
Slots Specific to This Method
Fill Factor
Type: Scalar Slot
Units: No Units
Alternate Units: No Units
Description: Fraction of the conservation pool (or conservation pool and diversion requests) to be requested in the Appropriation Request slot. If not defined, 1.0 is used.
I/O: Input
Links: No
Fill Factor is Series
This method allows the user to specify a series of fill factors in the slot.
Slots Specific to This Method
Fill Factors
Type: Series Slot
Units: No Units
Alternate Units: No Units
Description: Fraction of the conservation pool (or conservation pool and diversion requests) to be requested in the Appropriation Request slot. If not defined, 1.0 is used.
I/O: Input
Links: No