skip to main content
Diversion Pump Energy
The Diversion Pump Energy category is used to determine the Energy and Total Energy Cost based on the Diversion Intake Elevation, Outflow Elevation, Diversion, Pump Efficiency, and cost per Unit Energy. This method category is only available if Pumped Diversion is selected in the Available Flow category.
* None
This is the default method. It performs no energy calculations.
* Energy Equation and Cost
The Energy Equation and Cost method calculates Energy Consumption and Total Energy Cost. This method is only available when Pumped Diversion is selected in the Available Flow category.
Slots Specific to This Method
 Cost per Unit Energy
Type: TableSlot
Units: $per ENERGY
Description: Cost of each unit (MWH) of energy generated or consumed by the Diversion Object
Information: Used to determine the monetary value of the energy consumed by the Diversion Object.
I/O: Required input
 Energy Consumption
Type: SeriesSlot
Units: ENERGY
Description: Energy consumed by the Diversion Object
Information:  
I/O: Output only
 Outflow Elevation
Type: TableSlot
Units: LENGTH
Description: Water surface elevation at the outflow of the Diversion Object
Information:  
I/O: Required input
 Pump Efficiency
Type: TableSlot
Units: DECIMAL
Description: Efficiency of the pump in the Diversion Object
Information: Used in the calculation of the amount of energy consumed by the Diversion Object.
I/O: Required input
 Total Energy Cost
Type: SeriesSlot
Units: $
Description: the monetary value of the energy consumed by the Diversion Object
Information:  
I/O:  
Method Details  
The engineering algorithm used in this method is as follows.
    
    
    
Revised: 01/05/2024