Standalone or No Structure Slots
In addition to the general slots, the following slots exist for a standalone water user, or when the parent Agg Diversion Site has the No Structure method selected.
Note: The No Structure method is the default linking structure.
Depletion
Type: Series Slot
Units: Flow
Description: Amount of water consumed by the water user
Information:
I/O: Output only
Links: Usually not linked
Depletion Shortage
Type: Series Slot
Units: Flow
Description: Difference between the Depletion Requested and the Depletion
Information: This value is only calculated if Depletion Requested and Depletion are both valid.
I/O: Output only
Links: Usually not linked
Diversion
Type: Series Slot
Units: Flow
Description: Amount of water actually taken (diverted) by the water user
Information:
I/O: Optional; Can be input or calculated based on Diversion Requested and Incoming Available Water (see dispatch methods).
Links: Must be linked to the Diversion slot on the object being diverted from if using the No Structure.
Diversion Shortage
Type: Series Slot
Units: Flow
Description: Difference between the Diversion Requested and the Diversion
Information:
I/O: Output only
Links: Usually not linked
Incoming Available Water
Type: Series Slot
Units: Flow
Description: Water available to be diverted
Information: It is the user’s responsibility to link this slot to the appropriate slot on the object from which water is diverted if using No Structure.
I/O: Set via link
Links: Must be linked to the Available for Diversion slot on the object being diverted from if using No Structure. If using the sequential structure it is automatically linked to the Agg Diversion Site Total Diversion.