skip to main content
General Slots
 Total Available Water
Type: Series Slot
Units: FLOW
Description: signifies the water available for diversion from the reservoir or reach to which the diversion is connected
Information: Set by link propagation from the diverted object. The user is responsible for linking this slot with the object from which the water is diverted.
I/O: Optional; Could be input if not set via link.
 Total Depletion
Type: Series Slot
Units: FLOW
Description: The total amount consumed.
Information: Computed typically as Total Diversion minus Total Return Flow
I/O: Output only
 Total Depletion Requested
Type: Multislot
Units: FLOW
Description: a multislot showing the Depletion Requested for each Generator as well as the sum of all requested depletions.
Information:  
I/O: Optional; Can be input when there are no Generator elements and it is not linked.
 Total Diversion
Type: Series Slot
Units: FLOW
Description: Denotes the total water diverted to the Water Users
Information:  
I/O: Optional; must be specified if Total Diversion Requested is not given.
 Total Diversion Requested
Type: MultiSlot
Units: FLOW
Description: a multislot showing the Diversion Requested for each Generator as well as the sum of all requested diversions.
I/O: Optional; Can be input when there are no Generator elements and it is not linked.
 Total Return Flow
Type: Series Slot
Units: FLOW
Description: represents the portion of the water diverted which is not consumed
Information: It is the user’s responsibility to specify what is done with this data. If it is not linked to another object (that is, back to the reach/reservoir Return Flow slot), it is lost from the system.
I/O: Output only
 Total Depletion Shortage
Type: Series Slot
Units: Flow
Description: Represents the difference between Total Depletion Requested and Total Depletion.
Information: Computed as Total Depletion Requested - Total Depletion
I/O: Output only
 Total Diversion Shortage
Type: Series
Units: Flow
Description: The difference between Diversion Requested and Diversion
I/O: Output only
Revised: 12/06/2024