Flow from Downstream
These methods control how flows into the aquifer are represented from the downstream direction.
No Flow
No flows enter the Aquifer from downstream. This is the default method in this category
Compute Flow using Heads
This method computes the Flow from Downstream based on the difference in previous computational timestep heads and the conductance.
Slots Specific to This Method
Flow from Downstream
Type: Series
Units: Flow
Description: The flow that occurs into this Aquifer from the downstream object, usually another Aquifer
Information: For this method, the slot will have values only at the computational timestep. Positive values indicate flow into this Aquifer.
I/O: Output only
Links: Not linked for this method
Conductance Downstream
Type: Scalar
Units: AreaPerTime
Description: The conductance from the downstream object to this Aquifer.
Information: The Conductance Downstream must be the same as the conductance of the downstream object. If not, the conservation of mass will not be preserved.
I/O: Required Input
Links: Not Linkable
Head Downstream Previous
Type: Series
Units: Length
Description: The head of the downstream object from the previous computational timestep.
Information: This slot will have values only at the computational timestep.
I/O: Output only
Links: Link to the Head Previous of the downstream aquifer object.
Method Details
This method computes the flow into the Aquifer from the downstream:
(5.3) Note: This equation is applied at the computational timestep.