skip to main content
Water Quality : Agg Distribution Canal Water Quality : User Methods : Agg Distribution Canal Water Quality
Agg Distribution Canal Water Quality
The methods in this category add the necessary slots to the element. They also control the method selection on the member Distribution Canals.
* None
No water quality solution is performed. No slots are added.
* Propagate Salt
Following are the slots added to the
 Inflow Salt Concentration
Type: Series Slot
Units: Concentration
Description: Salt concentration associated with the inflow to the Agg Distribution Canal
I/O: Input, set by a rule, output or propagated via a link
 Inflow Salt Mass
Type: Series Slot
Units: Mass
Description: Salt mass associated with the inflow to the Agg Distribution Canal
I/O: Output only
 Outflow Salt Concentration
Type: Series Slot
Units: Concentration
Description: Salt concentration associated with the outflow from the Agg Distribution Canal
I/O: Input, set by a rule, output or propagated via a link
 Outflow Salt Mass
Type: Series Slot
Units: Mass
Description: Salt mass associated with the outflow from the Agg Distribution Canal
I/O: Output Only
Dispatch Methods
Following are the available dispatch method when Propagate Salt is selected.
* Solve Salt Mass
This method computes the total inflow and outflow salt mass only. The salt concentrations should come from the linked element objects or from upstream/downstream objects (or via input or rules).
Required Known Slots
• Total Inflow
• Total Outflow
• Inflow Salt Concentration
• Outflow Salt Concentration
Required Unknown Slots
• Inflow Salt Mass
• Outflow Salt Mass
This method does the following:
(2.1)    
(2.2)    
Revised: 11/11/2019