Reservoir Water Quality
Methods in this category are used to select the constituent and approach.
None
No water quality solution is performed. No slots are added.
Layered Salt
The layered salt slots are added (see
“Layered salt slots”). The Solve 2 Layer Salt dispatch method is made available.
Layered Temp
All of the temperature slots are added. The Solve 2 Layer Temperature dispatch method is made available.
Layered Temp and Salt
All of the temperature and the layered salt slots are added (see
“Layered salt slots”). This method makes the Solve 2 Layer Temp and Salt dispatch method available.
Layered Temp and DO
All of the temperature and DO slots are added. This method makes the Solve 2 Layer Temp and DO dispatch method available.
Layered Temp Salt and DO
All of the temperature and DO slots are added. The layered salt slots are also added (see
“Layered salt slots”). This method makes the Solve 2 Layer Temp Salt and DO dispatch method available.
Well Mixed Salt
The well-mixed salt slots are added (see
“Well-mixed Salt Slots”). This method makes the Solve Weight Factor Salt and Solve Pred-Corr Salt sets of dispatch methods available.
Segmented 2 Layer Salt
The segmented salt slots are added (see
“Segmented 2 Layer Salt slots”). This method makes the Solve Segmented 2 Layer Salt dispatch method available.
Outflow TDG using Tailwater Depth
This method models the spill, turbine release and mixed outflow TDG concentration based on the depth of the tailwater. See
“Total Dissolved Gas Methodology” for details on the method and all the slots.